Casella has introduced an upgraded pump for industrial air sampling. The Vortex 3E incorporates improved flow stability, environmental compensation, a brushless motor, and revised battery technology for monitoring airborne contaminants.


Occupational hygiene instrumentation specialist Casella has introduced the Vortex 3E high-flow air sampling pump, replacing its previous Vortex 3 model with equipment incorporating improved flow control, revised motor technology, and a redesigned battery arrangement.

Developed for area sampling of airborne contaminants, including asbestos and mould, the pump maintains flow within 5% during measurements and incorporates temperature and pressure compensation to improve the consistency of collected samples.

Casella has also introduced a brushless motor, enabling the equipment to use a smaller and lighter battery while increasing its operating duration. The pump incorporates an IP65-rated enclosure and a housing designed to connect with other units for easier handling.

The developments address practical requirements associated with occupational hygiene monitoring, where the reliability of laboratory results depends partly on establishing the volume of air sampled and maintaining appropriate collection conditions.

Air sampling pumps draw air through a collection medium selected according to the substance being investigated. Material retained during the sampling period can subsequently be analysed using a method suitable for identifying or measuring the target contaminant.

Calculating its airborne concentration requires an accurate assessment of the volume of air passing through the collection medium. Where flow remains constant throughout the sampling period, that volume can be calculated from the flow rate and measurement duration.

If actual flow differs from the recorded value, the estimated air volume may be inaccurate. The resulting concentration calculation could therefore understate or overstate the quantity of contaminant present, depending on the direction and magnitude of the discrepancy.

Maintaining consistent flow becomes particularly important as the resistance presented by the sampling equipment changes. Tubing, filter media, and associated connections all introduce pressure losses that the pump must overcome to maintain the selected flow.

Accumulated material can increase the resistance of a filter during sampling, requiring the flow control system to compensate within the operating capabilities of the equipment.

Environmental conditions can also influence volumetric measurements, depending on the operating characteristics and calibration of the instrumentation. Casella’s temperature and pressure compensation functions are intended to reduce the effects of those variations on sampling performance.

Phil Bradley, managing director at Casella, said: “The Vortex 3 was already recognised as a high-flow, high-powered air sampling pump. With the Vortex 3E, we have taken that capability further.”

Reducing the likelihood of unsuccessful samples has operational consequences beyond the performance of the instrument itself. Repeating a measurement requires additional personnel time and laboratory analysis, potentially delaying decisions that depend on the results.

Higher flow equipment can collect a specified volume of air over a shorter period where the applicable sampling methodology permits. This can be useful when investigating relatively low airborne concentrations, since collecting a larger volume can improve the analytical detection limit.

Increasing flow or measurement duration is not appropriate for every application, however. Excessive accumulation of particulate material can make a filter unsuitable for analysis, particularly in environments containing substantial quantities of dust unrelated to the contaminant being investigated.

The Health and Safety Executive’s guidance on asbestos analysis addresses the relationship between sampling conditions, air volume, and analytical performance. Equipment selection and operating parameters must correspond to the requirements of the particular monitoring method.

Area sampling also serves a different purpose from personal exposure monitoring. Measurements taken at a fixed location describe airborne conditions at that sampling point, whereas personal monitoring investigates the exposure experienced by an individual during specified activities.

The two approaches may provide complementary information within an occupational hygiene assessment, but their results cannot automatically be treated as interchangeable.

Casella’s adoption of a brushless motor addresses the electrical and mechanical demands associated with maintaining high airflow over extended periods.

Electronic commutation eliminates the brushes required in conventional brushed direct current motors, removing one source of mechanical wear. Improved motor efficiency can also reduce the energy required to operate the pump under comparable conditions.

The revised Vortex 3E battery arrangement is intended to take advantage of those improvements. Actual operating duration will depend on the selected flow, resistance of the sampling equipment, and battery condition.

Casella has not disclosed a quantified runtime improvement or the capacity of the replacement battery in its launch information.

The IP65 enclosure provides protection against dust ingress and water jets, supporting equipment deployment in demanding environments. Its interlocking housing arrangement also assists with transporting several units to sites requiring simultaneous area measurements.

Reliable monitoring remains dependent on appropriate equipment calibration, sampling strategies, sample handling, and laboratory procedures. Improved pump performance addresses one source of measurement variability within that wider process.

The Vortex 3E replaces Casella’s previous high-flow pump model, combining revised flow control and environmental compensation with changes to the motor, battery, and physical design intended to reduce the practical burden of equipment deployment and repeated sampling.


Stories for you


  • Wärtsilä extends EasyMax marine engine programme

    Wärtsilä extends EasyMax marine engine programme

    Wärtsilä has confirmed engine selections across Wagenborg’s six EasyMax vessels. Four additional cargo ships will use its modular Wärtsilä 25 engine platform, with equipment deliveries scheduled to begin in 2027.


  • Valmet introduces wireless industrial valve diagnostics

    Valmet introduces wireless industrial valve diagnostics

    Valmet has introduced wireless diagnostics for existing industrial valve controllers. Its Neles LoRa Communication Module transfers diagnostic summaries and alarms to a cloud-based monitoring platform where existing automation systems lack HART connectivity.